Rooftop PV Model

Rooftop PV Model

Methodology

Resolution and Accuracy
Solar and Weather
Power and Tuning
Data Sources and FAQ

Commercial Products

Commercial User GuideCommercial User Guide
Live and Forecast
Historic
Typical Meteorological Year (TMY)
Grid Aggregations
Geographic Horizon Angles

Hobbyist and Research Products

Home Hobbyist Accounts
Researchers and Academic Accounts

Help & Support

Changes and Announcements
Plans And Subscriptions
Evaluation and Testing
Authentication
Developer Guides
Third Party Applications
Troubleshooting and FAQs

Rooftop PV modelling methodology

Discover the rooftop PV model's input data, development, and diverse applications, from behind-the-meter Grid Aggregations to fleet production estimates.

This page outlines the PV modelling methodology and specifications of Solcast's Rooftop PV Model, through which users can access forecasts and modelled actuals with global-coverage across Live (-7 days to present moment), and Forecast (present moment to +14 days) time periods.

Model overview

The Solcast Rooftop PV Model, which produces the data parameter Rooftop PV Power Output (kW) is an empirical PV model, designed for modelling the production from rooftop PV systems (particularly fleets) with limited system specifications available. This model is limited to four system specifications: system azimuth and tilt, AC capacity, and a bulk loss factor. Because of this limited specification, there is no need for the creation of sites as with the Advanced PV model. Users simply make their API requests by referencing the latitude and longitude and capacity at a minimum, and also the azimuth tilt and loss factor if known. Some users cluster nearby systems (<5km) together, using known or assumed average values of these specifications.

The Solcast Rooftop PV Model is used by Solcast in the production of its behind-the-meter Grid Aggregations data product, which provides production estimated actual and forecast data for network assets or grid regions of any size from neighbourhood to continental scale. For more information on this product, refer to the Grid Aggregations Product Guide and Specifications document.

Input data

The Rooftop PV model uses Solcast's irradiance and weather data as its time-dynamic input. The Solcast data parameters used by the model include irradiance parameters Direct Normal Irradiance (DNI) and Diffuse Horizontal Irradiance (DHI), ambient Air Temperature, and a dynamic site-specific Snow Soiling Loss – Rooftop based on irradiance, temperature and precipitation. For more information about this input data, please refer to Solcast Irradiance and Weather Data Inputs and Algorithms documentation.

Model development and applications

The Solcast Rooftop PV model is designed to estimate production from a fleet of PV systems where system specifications, shading and other losses are poorly known at individual system level, and where system output measurement data is incomplete and/or not available in real time. The model can also be used to estimate system geometry and losses from measurement data. The original version of the model is described in Killinger et al., 2016 ("Projection of power generation between differently-oriented PV systems." Solar Energy 136: 153-165). During 2016 to 2019 the model was refined at the Australian National University in a $2.6M ARENA industry research project, and thereafter was licenced to Solcast. The model is now in operational use globally by a range of TSOs, Utilities and load forecasters in Australia, Taiwan, Korea, US, UK and Germany. Each deployment of the model has included local calibration and validation in concert with users.

The model is empirical, consisting of a fitted quadratic function of the plane-of-array irradiance and air temperature (and their interactions), and the loss factor. The quadratic coefficients and the loss factor are fitted to measured inverter output (AC) data from a range of PV systems targeted at performance for specific countries.

The model output is in terms of inverter output (AC) power. In cases where installed capacity data is in terms of module (DC) capacity, the model loss factors can be calibrated using inverter output (AC) power measurements. This approach does not invalidate the shape of model's power curves so long as very high inverter loading ratios (ILRs) (e.g. >1.25) are not so dominant amongst the fleet so as to overwhelm shading, soiling and other loss factors that drive the shape of the power curve.